LAMINATES: DK, DF AND TRACE WIDTH

What are the Dk and Df of Rogers RO3003?

Rogers RO3003 has a dielectric constant (Dk) of 3 and a loss factor (Df) of 0.001 at 10 GHz, as published by its maker. A 50 ohm surface microstrip over a 0.2 mm dielectric comes out about 0.469 mm wide on it, against 0.353 mm on standard FR-4.

  • Dielectric loss on that microstrip is about 0.031 dB per inch at 10 GHz, and the signal travels at about 130 ps per inch.
  • Buried as a stripline between planes 0.4 mm apart, 50 ohms needs a trace about 0.191 mm wide.

50 ohm surface microstrip, 1 oz copper

Dielectric heightTrace width on RO3003On standard FR-4
0.1 mm0.223 mm0.166 mm
0.2 mm0.469 mm0.353 mm
0.5 mm1.22 mm0.920 mm
1.6 mm3.97 mm3.02 mm

As published

PropertyValue
SeriesRO3000
Dk @ 10GHz3.00
Df @ 10GHz0.0010
TCDk (ppm/°C)−3
Thermal Cond. (W/m·K)0.50
Key Application77GHz radar, mmWave 5G

How this was counted

Dk and Df are the maker's published values at 10 GHz, from the MPBxChange material catalogue, which keeps each source's test frequency and method. Where a maker publishes a range, the midpoint is used. Widths are solved with the Hammerstad and Jensen microstrip equations and Wadell's stripline form, for 1 oz copper, and are a starting point: Dk moves with frequency, resin content and glass style, and a fabricator's field solver is the authority. Standard FR-4 here is the median of 22 FR-4 grades in the catalogue (Dk 4.4).